Skip to content
ESSign in

CISSP subtopic 3.9, Domain 33.9 Design site and facility security controls

This subtopic belongs to Domain 3, "Security Architecture and Engineering", which weighs 13% of the exam. Our bank holds 33 questions on it, split by difficulty as follows.

Theory in the Official Study Guide (10th ed.): chapter 10.

What gets asked on this subtopic

Concepts and situations that appear in our questions for this objective. The exam nearly always frames them as cases where you must decide.

  • Fire triangle
  • Fire classes
  • Preaction for data centers
  • Card skimming prevention
  • Passive infrared sensors and temperature
  • Power anomalies
  • UPS vs generator
  • Testing backup power
  • Humidity control
  • Positive pressurization
  • HVAC as attack surface
  • Access control vestibule
  • Server room design
  • Wiring closet security
  • Cable plant protection
  • Colocation physical security
  • Regional disaster planning
  • Fence heights
  • Security guards vs automation
  • Alarm types
  • Bollards
  • Media library controls
  • Off-site media storage
  • Evidence storage

Sample question

Domain 3/3.9 Design site and facility security controls

A national museum considers replacing its night guards entirely with motion sensors and cameras to save costs. The galleries often host late events and cleaning crews. Helga, the security director, warns the board. What is the MAIN advantage the museum would lose?

  1. AConstant coverage of the galleries
  2. BHuman judgment to assess and respond
  3. CDetection of movement after hours
  4. DFaster notification of the police
Show the answer

Correct answer: B. The question asks what guards offer that technology cannot. The clue is that the galleries "host late events and cleaning crews", so legitimate people move around after hours. Guards are flexible: they can assess unusual events, deter by presence, intervene, assist in emergencies and adapt to situations that sensors were not designed for. Their drawbacks are cost and reliability, so most facilities combine guards with sensors and cameras.

  • A. Incorrect. Sensors cover every gallery at once and never tire, so coverage would improve rather than be lost.
  • B. Correct. Galleries that host late events and cleaning crews need someone who can tell staff and guests from intruders and respond flexibly, which sensors cannot do.
  • C. Incorrect. Motion sensors detect movement reliably after hours, so detection itself would not be lost by removing guards.
  • D. Incorrect. A monitored alarm alerts responders automatically, so notification speed is not lost; telling staff and guests from intruders is.